Practice

Why

Use clear and descriptive parameter names

Makes the register list easy to scan and reduce the risk of misinterpretation

Apply consistent naming conventions for prefixes, units, and terminology

Helps users navigate large parameter sets efficiently

Group related parameters into logical, contiguous blocks in the register space

Improve readability and long‑term maintainability, since only contiguous parameters can be grouped in the same data set

Reserve address space for future parameters

Allows new items to be added contiguously, which is required for data sets

Use non‑volatile storage only when necessary

Unnecessary write operations can reduce device lifetime

Keep unrelated parameter types in separate register ranges

Avoids confusion and ensure predictable interpretation by external tools